DMX512/RDM Pinout Configuration (ANSI E1.11)
*CAT5, CAT5E, CAT6 cable must be spliced into XLR cable from console
or utilize 5 pin XLR to RJ45 adaptor.
Pin (Wire) # Wire Color
DMX512 Function per ANSI E1.11
Used in Incito DMXR (HPEPP)
1 white / orange Data 1 +
2 orange Data 1 -
3 white / green Data 2 + (not used for Incito)
6 green Data 2 - (not used for Incito)
4 blue Not Assigned
5 white / blue Not Assigned
7 white / brown Data 1 common (0 v)
8 brown Data 2 common (0 v)
Pin (Wire) # Wire Color
DMX512 Function per ANSI E1.11
Used in Incito DMXR (HPEPP)
1 white / orange Data 1 +
2 orange Data 1 -
3 white / green Data 2 + (not used for Incito)
4 blue Not Assigned
5 white / blue Not Assigned
6 green Data 2 - (not used for Incito)
7 white / brown Data 1 common (0 v)
8 brown Data 2 common (0 v)
DMX Network Cat-5 / Cat-5e / Cat 6 Wiring (sorted by pair)
DMX Network Cat-5 / Cat-5e / Cat 6 Wiring (sorted by pin #)